Skip to main content Skip to main navigation menu Skip to site footer
  • Register
  • Login
  • Menu
  • Home
  • Current
  • Archives
  • Announcements
  • About
    • About the Journal
    • Submissions
    • Editorial Team
    • Privacy Statement
    • Contact
  • Register
  • Login

Quality in Sport

Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review
  • Home
  • /
  • Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review
  1. Home /
  2. Archives /
  3. Vol. 79 (2026) /
  4. Medical Sciences

Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review

Authors

  • Oliwia Gałczyńska Medical university of lublin https://orcid.org/0009-0004-0738-8199
  • Zuzanna Zofia Cecot https://orcid.org/0009-0009-6280-4278
  • Jarosław Józef Kucharski https://orcid.org/0009-0007-7470-6451
  • Maciej Mariusz Lesiczka https://orcid.org/0009-0003-3234-9549
  • Julia Weronika Duszejko https://orcid.org/0009-0000-0974-5170
  • Filip Lenartowicz Medical university of lublin https://orcid.org/0009-0004-1980-9640
  • Anna Maciaszczyk https://orcid.org/0009-0003-3872-0310
  • Katarzyna Kuklińska https://orcid.org/0009-0007-1242-3958
  • Alicja Martyna Lewczuk https://orcid.org/0009-0004-8827-3739
  • Dawid Oskar Mazurek https://orcid.org/0009-0004-7501-5941

DOI:

https://doi.org/10.12775/QS.2026.79.76805

Keywords

resistanse training, cuff size, Measurement accuracy, Arm circumference, Bodybuilding, Blood pressure measurement, training, arterial hypertension, physical exercise, isometric training, aerobic training

Abstract

Background: Accurate resting blood pressure measurement in adults engaged in resistance training may be complicated by large upper-arm circumference and inadequate cuff fit. Evidence from general adult populations requires careful interpretation when applied to muscular arms.

Aim: To evaluate evidence on cuff selection and blood pressure measurement accuracy and assess its applicability to adults engaged in resistance training.

Materials and Methods: This narrative review combined targeted Europe PMC searches restricted to PubMed records with supplementary publisher and reference-list searches. Twenty-five publications were assessed in full text. One additional study involving competitive bodybuilders was discussed separately using its indexed abstract. Findings were synthesized qualitatively, considering study design, cuff characteristics, reference methods and population applicability.

Results: Studies in general adult populations demonstrated that cuff size, geometry, positioning and device configuration can affect blood pressure readings. In a study of 193 competitive bodybuilders, the abstract reported that medium cuffs produced systolic readings averaging 8.2 mmHg higher than large cuffs in participants with arm circumference exceeding 33 cm. This represents between-cuff disagreement rather than established error against an independent reference; unavailable full text limited methodological appraisal. The reviewed evidence supports measuring arm circumference, assessing cuff fit and using validated device–cuff combinations. It does not establish a universally optimal cuff or a muscularity-specific correction factor.

Conclusions: Appropriate cuff selection is essential when interpreting blood pressure in resistance-trained adults. Findings from other populations support standardized measurement but require dedicated validation in muscular arms. Persistently elevated readings after technical correction warrant clinical evaluation.

References

1. McEvoy JW, McCarthy CP, Bruno RM, Brouwers S, Canavan MD, Ceconi C, Christodorescu RM, Daskalopoulou SS, Ferro CJ, Gerdts E, Hanssen H, Harris J, Lauder L, McManus RJ, Molloy GJ, Rahimi K, Regitz-Zagrosek V, Rossi GP, Sandset EC, Scheenaerts B, Staessen JA, Uchmanowicz I, Volterrani M, Touyz RM, ESC Scientific Document Group. 2024 ESC Guidelines for the management of elevated blood pressure and hypertension. Eur Heart J. 2024;45(38):3912-4018. https://doi.org/10.1093/eurheartj/ehae178. PMID: 39210715. Full text: https://oup.silverchair-cdn.com/article-minimal/7741010

2. Muntner P, Shimbo D, Carey RM, Charleston JB, Gaillard T, Misra S, Myers MG, Ogedegbe G, Schwartz JE, Townsend RR, Urbina EM, Viera AJ, White WB, Wright JT Jr. Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association. Hypertension. 2019;73(5):e35-e66. https://doi.org/10.1161/hyp.0000000000000087. PMID: 30827125. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC11409525/

3. Muntner P, Einhorn PT, Cushman WC, Whelton PK, Bello NA, Drawz PE, Green BB, Jones DW, Juraschek SP, Margolis KL, Miller ER 3rd, Navar AM, Ostchega Y, Rakotz MK, Rosner B, Schwartz JE, Shimbo D, Stergiou GS, Townsend RR, Williamson JD, Wright JT Jr, Appel LJ, 2017 National Heart, Lung, and Blood Institute Working Group. Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research: JACC Scientific Expert Panel. J Am Coll Cardiol. 2019;73(3):317-335. https://doi.org/10.1016/j.jacc.2018.10.069. PMID: 30678763. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC6573014/

4. Schweiger V, Niederseer D, Schmied C, Attenhofer-Jost C, Caselli S. Athletes and Hypertension. Curr Cardiol Rep. 2021;23(12):176. https://doi.org/10.1007/s11886-021-01608-x. PMID: 34657248. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC8520516/

5. Leddy JJ, Izzo J. Hypertension in athletes. J Clin Hypertens (Greenwich). 2009;11(4):226-233. https://doi.org/10.1111/j.1751-7176.2009.00100.x. PMID: 19614807. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC8673157/

6. Ishigami J, Charleston J, Miller ER 3rd, Matsushita K, Appel LJ, Brady TM. Effects of Cuff Size on the Accuracy of Blood Pressure Readings: The Cuff(SZ) Randomized Crossover Trial. JAMA Intern Med. 2023;183(10):1061-1068. https://doi.org/10.1001/jamainternmed.2023.3264. PMID: 37548984. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC10407761/

7. Palatini P, Asmar R. Cuff challenges in blood pressure measurement. J Clin Hypertens (Greenwich). 2018;20(7):1100-1103. https://doi.org/10.1111/jch.13301. PMID: 30003699. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC8030978/

8. Shahi S, Jackson SL, Streeter TE, He S, Wall HK. Cuff Size Variation Across Manufacturers of Home Blood Pressure Devices: A Current Patient Dilemma. Am J Hypertens. 2023;36(10):532-535. https://doi.org/10.1093/ajh/hpad060. PMID: 37422909. Full text: https://oup.silverchair-cdn.com/article-minimal/7221751

9. Picone DS, Padwal R, Stergiou GS, Cohen JB, McManus RJ, Eckert S, Asayama K, Atkins N, Rakotz M, Lombardi C, Brady TM, Sharman JE. How to find and use validated blood pressure measuring devices. J Hum Hypertens. 2023;37(2):108-114. https://doi.org/10.1038/s41371-022-00718-5. PMID: 35778537. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC9957729/

10. Kallioinen N, Hill A, Horswill MS, Ward HE, Watson MO. Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review. J Hypertens. 2017;35(3):421-441. https://doi.org/10.1097/hjh.0000000000001197. PMID: 27977471. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC5278896/

11. Mousavi SS, Reyna MA, Clifford GD, Sameni R. A Survey on Blood Pressure Measurement Technologies: Addressing Potential Sources of Bias. Sensors (Basel). 2024;24(6):1730. https://doi.org/10.3390/s24061730. PMID: 38543993. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC10976157/

12. Stergiou GS, Palatini P, Parati G, O'Brien E, Januszewicz A, Lurbe E, Persu A, Mancia G, Kreutz R, European Society of Hypertension Council and the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability. 2021 European Society of Hypertension practice guidelines for office and out-of-office blood pressure measurement. J Hypertens. 2021;39(7):1293-1302. https://doi.org/10.1097/hjh.0000000000002843. PMID: 33710173. Full text: https://research.dial.uclouvain.be/bitstreams/b37ef7a1-70a2-49d3-89f5-8f101c30b4f1/download

13. Palatini P, Frick GN. Techniques for self-measurement of blood pressure: limitations and needs for future research. J Clin Hypertens (Greenwich). 2012;14(3):139-143. https://doi.org/10.1111/j.1751-7176.2011.00586.x. PMID: 22372772. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC8108913/

14. Irving G, Holden J, Stevens R, McManus RJ. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review. BMJ Open. 2016;6(11):e012429. https://doi.org/10.1136/bmjopen-2016-012429. PMID: 27810973. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC5129068/

15. Padwal R, Campbell NRC, Schutte AE, Olsen MH, Delles C, Etyang A, Cruickshank JK, Stergiou G, Rakotz MK, Wozniak G, Jaffe MG, Benjamin I, Parati G, Sharman JE. Optimizing observer performance of clinic blood pressure measurement: a position statement from the Lancet Commission on Hypertension Group. J Hypertens. 2019;37(9):1737-1745. https://doi.org/10.1097/hjh.0000000000002112. PMID: 31034450. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC6686964/

16. Bonso E, Saladini F, Zanier A, Benetti E, Dorigatti F, Palatini P. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertens Res. 2010;33(11):1186-1191. https://doi.org/10.1038/hr.2010.146. PMID: 20686489. Full text: https://www.microlife.ua/media/4972/download/Bonso%2C%202010%2C%20BP%20A100%20rigid%20conical%20cuff.pdf?v=1

17. Palatini P, Fania C, Ermolao A, Battista F, Saladini F. Use of Anthropometric Indices to Identify Appropriate Cuff Shapes for Blood Pressure Measurement: Normative Data for Adults. Am J Hypertens. 2022;35(6):526-532. https://doi.org/10.1093/ajh/hpac003. PMID: 35100337. Full text: https://oup.silverchair-cdn.com/article-minimal/6518148

18. Stergiou GS, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S, Frick G, Friedman B, Graßl T, Ichikawa T, Ioannidis JP, Lacy P, McManus R, Murray A, Myers M, Palatini P, Parati G, Quinn D, Sarkis J, Shennan A, Usuda T, Wang J, Wu CO, O'Brien E. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement. J Hypertens. 2018;36(3):472-478. https://doi.org/10.1097/hjh.0000000000001634. PMID: 29384983. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC5796427/

19. Brady TM, Padwal R, Blakeman DE, Farrell M, Frieden TR, Kaur P, Moran AE, Jaffe MG. Blood pressure measurement device selection in low-resource settings: Challenges, compromises, and routes to progress. J Clin Hypertens (Greenwich). 2020;22(5):792-801. https://doi.org/10.1111/jch.13867. PMID: 32347665. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC8030027/

20. TRUE Consortium. Recommended Standards for Assessing Blood Pressure in Human Research Where Blood Pressure or Hypertension Is a Major Focus. Kidney Int Rep. 2017;2(4):733-738. https://doi.org/10.1016/j.ekir.2017.02.009. PMID: 29142989. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC5678635/

21. Mihailidou AS. Measuring blood pressure accurately. Aust Prescr. 2026;49(2):50-54. https://doi.org/10.18773/austprescr.2026.016. PMID: 42039705. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC13107338/

22. Oguaju B, Lau D, Padwal R, Ringrose J. Inter-observer reliability and anatomical landmarks for arm circumference to determine cuff size for blood pressure measurement. J Clin Hypertens (Greenwich). 2024;26(7):867-871. https://doi.org/10.1111/jch.14854. PMID: 38980266. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC11232441/

23. Bilo G, Sala O, Perego C, Faini A, Gao L, Głuszewska A, Ochoa JE, Pellegrini D, Lonati LM, Parati G. Impact of cuff positioning on blood pressure measurement accuracy: may a specially designed cuff make a difference?. Hypertens Res. 2017;40(6):573-580. https://doi.org/10.1038/hr.2016.184. PMID: 28077860. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC5506235/

24. Liu H, Zhao D, Sabit A, Pathiravasan CH, Ishigami J, Charleston J, Miller ER 3rd, Matsushita K, Appel LJ, Brady TM. Arm Position and Blood Pressure Readings: The ARMS Crossover Randomized Clinical Trial. JAMA Intern Med. 2024;184(12):1436-1442. https://doi.org/10.1001/jamainternmed.2024.5213. PMID: 39373998. Full text: https://pmc.ncbi.nlm.nih.gov/articles/PMC11459360/

25. Jackson SL, Gillespie C, Shimbo D, Rakotz M, Wall HK. Blood Pressure Cuff Sizes for Adults in the United States: National Health and Nutrition Examination Survey, 2015-2020. Am J Hypertens. 2022;35(11):923-928. https://doi.org/10.1093/ajh/hpac104. PMID: 36066190. Full text: https://pmc.ncbi

Quality in Sport

Downloads

  • PDF

Published

2026-11-15

How to Cite

1.
GAŁCZYŃSKA, Oliwia, CECOT, Zuzanna Zofia, KUCHARSKI, Jarosław Józef, LESICZKA, Maciej Mariusz, DUSZEJKO, Julia Weronika, FILIP LENARTOWICZ, MACIASZCZYK, Anna, KUKLIŃSKA, Katarzyna, LEWCZUK, Alicja Martyna and MAZUREK, Dawid Oskar. Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review. Quality in Sport. Online. 15 November 2026. Vol. 79, p. 76805. [Accessed 15 November 2026]. DOI 10.12775/QS.2026.79.76805.
  • ISO 690
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
Download Citation
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

Issue

Vol. 79 (2026)

Section

Medical Sciences

License

Copyright (c) 2026 Oliwia Gałczyńska, Zuzanna Zofia Cecot, Jarosław Józef Kucharski, Maciej Mariusz Lesiczka, Julia Weronika Duszejko, Filip Lenartowicz, Anna Maciaszczyk, Katarzyna Kuklińska, Alicja Martyna Lewczuk, Dawid Oskar Mazurek

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

Stats

Number of views and downloads: 2
Number of citations: 0

Search

Search

Browse

  • Issue archive

User

User

Current Issue

  • Atom logo
  • RSS2 logo
  • RSS1 logo

Information

  • For Readers
  • For Authors
  • For Librarians

Newsletter

Subscribe Unsubscribe

Tags

Search using one of provided tags:

resistanse training, cuff size, Measurement accuracy, Arm circumference, Bodybuilding, Blood pressure measurement, training, arterial hypertension, physical exercise, isometric training, aerobic training
Up

Akademicka Platforma Czasopism

Najlepsze czasopisma naukowe i akademickie w jednym miejscu

apcz.umk.pl

Partners

  • Akademia Ignatianum w Krakowie
  • Akademickie Towarzystwo Andragogiczne
  • Fundacja Copernicus na rzecz Rozwoju Badań Naukowych
  • Instytut Historii im. Tadeusza Manteuffla Polskiej Akademii Nauk
  • Instytut Kultur Śródziemnomorskich i Orientalnych PAN
  • Instytut Tomistyczny
  • Karmelitański Instytut Duchowości w Krakowie
  • Ministerstwo Kultury i Dziedzictwa Narodowego
  • Państwowa Akademia Nauk Stosowanych w Krośnie
  • Państwowa Akademia Nauk Stosowanych we Włocławku
  • Państwowa Wyższa Szkoła Zawodowa im. Stanisława Pigonia w Krośnie
  • Polska Fundacja Przemysłu Kosmicznego
  • Polskie Towarzystwo Ekonomiczne
  • Polskie Towarzystwo Ludoznawcze
  • Towarzystwo Miłośników Torunia
  • Towarzystwo Naukowe w Toruniu
  • Uniwersytet im. Adama Mickiewicza w Poznaniu
  • Uniwersytet Komisji Edukacji Narodowej w Krakowie
  • Uniwersytet Mikołaja Kopernika
  • Uniwersytet w Białymstoku
  • Uniwersytet Warszawski
  • Wojewódzka Biblioteka Publiczna - Książnica Kopernikańska
  • Wyższe Seminarium Duchowne w Pelplinie / Wydawnictwo Diecezjalne „Bernardinum" w Pelplinie

© 2021- Nicolaus Copernicus University Accessibility statement Shop